CCA Indoor Wiring UTP 305m Bare Copper Wire 23awg Standard Cat6 Lan cable
▌ Product description
The Category 6 Cable is constructed as a U/UTP Cable and exceeds the relevant performance requirements of ISO/IEC 11801-2 and TIA/ANSI 568-C.2 EN50173, IEC 61156-5, EN 50288-10-1. The LSHF-FR sheath conforms with fire rating IEC 60332-1, 60332-3-24, 60754-2 and 61034. The copper conductor is AWG 23 and the cable has an nominal overall diameter of 7.1mm. This cable complies with the requirements within the Construction Products regulations EN50575:2014+A1:2016 - Power, control and communication cables. Cables for general applications in construction works subject to reaction to fire requirements.
▌Construction
▌Standard / Certificate
▌Appliacation
Broadband Ethernet communication, generic cabling system of intelligent building or residential community, local area network system, computer network distribution system, test equipment and cable TV system, anti-theft monitoring system, etc.
▌Parameter
REACTION TO FIRE
CHARACTERISTIC | IEC STANDARD | EN STANDARD | CPR RATING |
Classification / EuroClass | - | EN 13501-6 | Cca s1a d1 a1 |
Single Cable Flame Rating | IEC 60332-1-2 | EN 60332-1-2 | Pass |
Smoke Emission | IEC 61034 | EN 61034 | Pass |
Acid Gas Emission | IEC 60754 | EN 60754 | Pass |
PRIMARY ELECTRICAL PARAMETERS
CHARACTERISTIC | SPECIFICATION | TYPICAL PERFORMANCE @ 20°C |
Conductor Loop Resistance | Max 19 Ω/100m | 16 Ω/100m |
Conductor Resistance Unbalance | Max 2% | 0.1% |
Insulation Resistance | >5GΩ.km | >50GΩ.km |
Dielectric Strength | 2500 Vdc/2secs | Pass |
SECONDARY ELECTRICAL PARAMETERS
CHARACTERISTIC | SPECIFICATION | TYPICAL PERFORMANCE @ 20°C |
Velocity of Propagation | <534nsec/100m @ 100MHz | 505nsec/100m @ 100MHz |
Delay Skew | Max 45nsec/100m @100MHz | 30nsec/100m @ 100MHz |
Mean Characteristic Impedance | 100Ω +/- 5Ω @ 100MHz | 100Ω ± 3Ω @ 100MHz |
Transverse Conversion Loss (TCL) | ≥50-10log(f)dB | 61dB @ 10MHz |
ELECTRICAL PERFORMANCE
Frequency (MHz) | 1 | 4 | 10 | 20 | 100 | 200 | 250 | |
Insertion Loss (dB/100m) max | Standard | 2.0 | 3.8 | 6.0 | 8.5 | 19.8 | 29.0 | 32.8 |
NEXT (dB) min | Standard | 74.3 | 65.3 | 59.3 | 54.8 | 44.3 | 39.8 | 38.3 |
PSNEXT (dB) min | Standard | 72.3 | 63.3 | 57.3 | 52.8 | 42.3 | 37.8 | 36.3 |
ACR-F (dB) min | Standard | 67.8 | 55.8 | 47.8 | 41.8 | 27.8 | 21.8 | 19.8 |
PSACR-F (dB) min | Standard | 64.8 | 52.8 | 44.8 | 38.8 | 24.8 | 18.8 | 16.8 |
Return Loss (dB) min | Standard | N/A | 23.0 | 25.0 | 25.0 | 20.1 | 18.0 | 17.3 |
INSTALLATION
Temperature (Installation) | 0°C to +50°C |
Temperature (Operation) | -20°C to +75°C |
Max Tensile Load (Installation) | 10kg |
Segregation Class | Class B |
Min Bend Radius (Installation) | 8 x Outer Diameter |
Min Bend Radius (Operation) | 4 x Outer Diameter |
Field Test NVP Value | 0.66 |
▌STANDARD PACKAGING SPECIFICATIONS – REELS
Part Number |
Packaging Length (m) |
Color |
Nominal Cable Diameter (mm) | Nominal Cable Weight (kg/km) |
Reel Size Flange Diameter x Width (mm) |
Gross Weight (kg/Item) | Items Per Pallet |
C6U-Cca-500GN | 500 | Green† | 6.15 | 44.9 | 400 x 310 | 24.5 | 18 |
C6U-Cca-1000GN | 1000 | Green† | 6.15 | 44.9 | 465 x 390 | 47.9 | 6 |
▌STANDARD PACKAGING SPECIFICATIONS - BOXES
Part Number |
Packaging Length (m) |
Color |
Nominal Cable Diameter (mm) | Nominal Cable Weight (kg/km) | Box Size L x W x H (mm) | Gross Weight (kg/Item) | Items Per Pallet |
C6U-Cca-Rlx-305GN | 305 | Green† | 6.15 | 44.9 | 435 x 265 x 405 | 14.4 | 21/14†† |
▌Panking
Cable weight | Gross weight | |||||||
9.3kg | 10kg | |||||||
Box size (CM) | Specifications | |||||||
21.5×35×35 | 305m/box |
▌Application scenario
Network TV | Desktop computer | Notebook computer | Printer |
Router | Set top box | Cabinet | Camera |
▌Frequently asked question (FAQ)
Q: Are you a cable and wire manufacturer?
— Yes, we are a professional wire and cable manufacturer.
Q: Can you offer a discount on cables?
— The price is negotiable according to the specification and quantity.
Q: Can you offer FREE samples?
— Yes,FREE samples are available, you just take care of the freight fee.
Q: What about your MOQ?
— Usually, our MOQ is 5000 Meters, but we’ d love to talk about your MOQ.
Q: Do you accept customize cables?
— Yes, we are more than happy to make OEM and ODM for you.
Q: How long is the lead time?
— Usually it’s about 10-14 days.