GYFXTY 12 Core Outdoor Rated Fiber Optic Cable Central Loose Tube Non Metallic
GYFXTY 12-core outdoor fiber optic cable. All-dielectric, non-metallic & non-armored. Excellent lightning & EMI resistance. PE sheath for UV/moisture protection. Ideal for aerial, duct, and long-distance telecom.
12 core outdoor fiber optic cable
,GYFXTY loose tube fiber optic cable
,non metallic Outdoor fiber optic cable
GYFXTY all-dielectric outdoor cables use central loose tube structure, which are filled with water-resistant filling compound to provide crucial protection for the fiber. Over the tube, water-blocking material is applied to keep the cable watertight. Two parallel fiber reinforced plastics (FRP) are placed at the two sides, which has an excellent anti-electromagnet ability and lightning resistance performance. The cable is completed with a single polyethylene (PE) sheath. It is especially suitable for installation in aerial for long-distance and bureau communication and wiring in multiple minefields and electromagnetic interfering places.
- Aerial installation
- Trunk power transmission system
- Access network and local network
- Electromagnetic interfering places
- Outdoor distribution, lightning protection
- Long-distance communication and bureau communication
- Good mechanical and temperature performance
- High strength loose tube that is hydrolysis resistant
- Special tube filling compound ensure a critical protection of fiber
- Two parallel FRPs ensure tensile strength
- PE sheath protects cable from ultraviolet radiation
- Small diameter, light weight and easy installation
| Parameter | G.652 | 50/125 µm | 62.5/125 µm |
|---|---|---|---|
| Attenuation @ 850 nm | <3.0 dB/km | <3.3 dB/km | |
| Attenuation @ 1300 nm | <1.0 dB/km | <1.0 dB/km | |
| Attenuation @ 1310 nm | <0.36 dB/km | ||
| Attenuation @ 1550 nm | <0.22 dB/km | ||
| Bandwidth @ 850 nm | >500 MHz·km | >200 MHz·km | |
| Bandwidth @ 1300 nm | >500 MHz·km | >500 MHz·km | |
| Numerical Aperture | 0.200±0.015 NA | 0.275±0.015 NA | |
| Cable Cut-off Wavelength λcc | <1260 nm |
| Fiber Count | Nominal Diameter (mm) | Nominal Weight (kg/km) | Allowable Tensile Load (N) | Allowable Crush Resistance (N/100mm) | Bending Radius |
|---|---|---|---|---|---|
| Long Term | Short Term | Static / Dynamic | |||
| 2-12 | 8.2 | 65 | 600 | 1500 / 300 | 10D / 20D |


Cable is supplied in lengths as specified in PI or as requirement. Each length will be shipped on a separate iron-wooden drum. The minimum barrel diameter of the drum will not be less than 30 times the cable diameter.
The cable ends will be sealed with plastic protection caps to prevent water penetration. The ends will be easily accessible for testing. A final inspection test report with attenuation performance data for each fiber is attached inside the drum.