Ποιότητα Overhead Ground Wire OPGW Cable Aluminum Clad Steel Wire Optical Fiber OPGW Cable Εργοστάσιο
Ποιότητα Overhead Ground Wire OPGW Cable Aluminum Clad Steel Wire Optical Fiber OPGW Cable Εργοστάσιο

Overhead Ground Wire OPGW Cable Aluminum Clad Steel Wire Optical Fiber OPGW Cable

Overhead Ground Wire OPGW Cable Aluminum Clad Steel Wire Optical Fiber OPGW Cable
Βασικές Ιδιότητες
Χώρα Προέλευσης
Dong Guan Κίνα
Επωνυμία
MingTong
Πιστοποιητικό
ISO
Μοντέλο Προϊόντος
OPGW
Εμπορικά Ακίνητα
MOQ
20 χλμ
Τιμή Μονάδων
500-5000RNB/KM
Τρόπος Πληρωμής
L/C,T/T
Δυνατότητα Ανεφοδιασμού
200km/Day
Σύνοψη του προϊόντος

Product Description OPGW Optical Ground Wire 24 Core Outdoor Aerial Fiber Optic Cable 1. Description The central Al-covered steel tube is surrounded by single or double layers of aluminum clad steel wires(ACS) or mix ACS wires and aluminum alloy wires. Al-covered Stainless Steel tube design ...

Λεπτομέρειες προιόντος
Επισημαίνω:

steel opgw cable

,

steel overhead ground wire

,

g652d opgw cable

Application: Replacemnet του εναέριου επίγειου καλωδίου
Fiber: G652D, G657A1, G657A2
Type: επαγγελματικές κατασκευές
Cable Diameter: 918.2mm
Package: σίδηρος-ξύλινο εξέλικτρο
Highlight: Καλώδιο Overhead Cire Opgw, καλώδιο OPGW από χαλύβδινο αλουμίνιο, καλώδιο οπτικής ίνας Overhead Opgw
Jacket Material: αλουμίνιο-ντυμένο steel/ACS
Name: opgw καλώδιο
Περιγραφή προϊόντων
Product Description

OPGW Optical Ground Wire 24 Core Outdoor Aerial Fiber Optic Cable

1. Description

The central Al-covered steel tube is surrounded by single or double layers of aluminum clad steel wires(ACS) or mix ACS wires and aluminum alloy wires. Al-covered Stainless Steel tube design increases the cross section of AL, to reach a better fault current and lightning resistance performance. Apply to the transmission line which requires small diameter and large fault current.

2. Features

• Large diameter, large fiber capacity

• The structure is stable and the reliability is high

• Excellent capability against side and outstanding short circuit current capacity

• The optimum stranding design can obtain the surplus length of secondary optical fiber

• The number of strands can be designed in two or three layers

• Match with common ground wires


3.Speicfication


Structure Max fiber count AS sectional area Dia.(mm) Weight (kg/km) RTS(kN) 20°C DC resistance (O/km) 40-200°C Allowable short circuit current capacity(KA2.S )
OPGW-24B1.3-100-[118;50] 1/2.6/20AS+5/2.5/20AS+ 24 ≈100 13.2 ≤674 ≥118 ≤0.93 ≥50
11/2.8/20AS,Unit 1/2.5
OPGW-24B1.3-100-[60;74] 1/2.6/40AS+5/2.5/40AS+ 24 ≈100 13.2 ≤479 ≥60 ≤0.49 ≥74
11/2.8/40AS,Unit 1/2.5
OPGW-24B1.3-110-[133;63] 1/2.6/20AS+5/2.5/20AS+ 24 ≈110 14 ≤760 ≥133 ≤0.83 ≥63
10/3.2/20AS,Unit 1/2.5
OPGW-24B1.3-110-[140;68] 1/2.8/20AS+5/2.7/20AS+ 24 ≈110 14.3 ≤791 ≥140 ≤0.80 ≥68
11/3.05/20AS,Unit 1/2.6
OPGW-24B1.3-110-[67;95] 1/2.9/20AS+5/2.8/20AS+ 24 ≈37 14.1 ≤473 ≥67 ≤0.40 ≥95
12/2.8/AA,Unit 1/2.7 ≈74(AA)

Note : This datasheet can only be a reference, but not a supplement to the contract. Please contact the sales for the details.


Overhead Ground Wire OPGW Cable Aluminum Clad Steel Wire Optical Fiber OPGW Cable 0


4.Structure and Product Pictures

Overhead Ground Wire OPGW Cable Aluminum Clad Steel Wire Optical Fiber OPGW Cable 1Overhead Ground Wire OPGW Cable Aluminum Clad Steel Wire Optical Fiber OPGW Cable 2

5. Packing and Shipping

Cable is supplied in lengths as specified in PI or as requirement. Each length will be shipped on a separate iron-wooden drum. The minimum barrel diameter of the drum will not be less than 30 times the cable diameter.
The cable ends will be sealed with plastic protection caps to prevent water penetration. The ends will be easily accessible for testing. A final inspection test report with attenuation performance data for each fiber is attached inside the drum.


Overhead Ground Wire OPGW Cable Aluminum Clad Steel Wire Optical Fiber OPGW Cable 3